`__
specifies the number of instances that are required based upon the
cloud size (number of nodes).
.. _4223-network-nodes:
4.2.2.3. Network nodes
^^^^^^^^^^^^^^^^^^^^^^
Networks nodes are mainly used for L3 traffic management for overlay
tenant network (see more detail in section 4.3.1.5 Neutron)
- BIOS requirements
=================== ======
BIOS/boot Parameter Value
=================== ======
Boot disks RAID 1
=================== ======
- How many nodes to meet SLA
- Minimum 2 nodes for high availibility using VRRP.
- HW specifications
- 3 NICs card are needed if we want to isolate the different flows:
- 1 NIC for Tenant Network
- 1 NIC for External Network
- 1 NIC for Other Networks (PXE, Mngt ...)
- Sizing rules
- Scale out of network node is not easy
- DVR can be an option for large deployment (see more detail in
chapter 4.3.1.5 - Neutron)
.. _4224-storage-nodes:
4.2.2.4. Storage nodes
^^^^^^^^^^^^^^^^^^^^^^
- BIOS requirements
=================== ======
BIOS/boot Parameter Value
=================== ======
Boot disks RAID 1
=================== ======
- HW specifications
- How many nodes to meet SLA
- Sizing rules
.. _4225-compute-nodes:
4.2.2.5. Compute Nodes
^^^^^^^^^^^^^^^^^^^^^^
This section specifies the compute node configurations to support the
Basic and High Performance profiles; in OpenStack this would be
accomplished by specifying the configurations when creating "flavors".
The cloud operator may choose to implement certain profile-extensions
(`RM 2.4 Profile
Extensions <../../../ref_model/chapters/chapter02.md#242-profile-extensions-specialisations>`__)
as a set of standard configurations, of a given profile, capturing some
of the variability through different values or extra specifications.
- The software and hardware configurations are as specified in the
`Reference Model chapter
5.4 <../../../ref_model/chapters/chapter05.md#5.4>`__
- BIOS requirement
- The general BIOS requirements are described in the `Reference
Model chapter
5.4 <../../../ref_model/chapters/chapter05.md#5.4>`__
**Example Profiles and their Extensions**
The Reference Model specifies the Basic (B) and High Performance (H)
profile types. The Reference Model also provides a choice of network
acceleration capabilities utilising, for example, DPDK and SR-IOV
technologies. Table 4-2 lists a few simple examples of profile
extensions and some of their capabilities.
+-------+-------+-------+-----+-------+------+-------+-------+
| Pr | D | CPU | SMT | CPU | NUMA | Huge | Data |
| ofile | escri | Alloc | | Pi | | Pages | Tr |
| Exten | ption | ation | | nning | | | affic |
| sions | | Ratio | | | | | |
+=======+=======+=======+=====+=======+======+=======+=======+
| B1 | Basic | 1:1 | Y | N | N | N | OVS-k |
| | Prof | | | | | | ernel |
| | ileNo | | | | | | |
| | CPU | | | | | | |
| | ov | | | | | | |
| | er-su | | | | | | |
| | bscri | | | | | | |
| | ption | | | | | | |
| | pr | | | | | | |
| | ofile | | | | | | |
| | exte | | | | | | |
| | nsion | | | | | | |
+-------+-------+-------+-----+-------+------+-------+-------+
| B4 | Basic | 4:1 | Y | N | N | N | OVS-k |
| | Prof | | | | | | ernel |
| | ile4x | | | | | | |
| | CPU | | | | | | |
| | ov | | | | | | |
| | er-su | | | | | | |
| | bscri | | | | | | |
| | ption | | | | | | |
| | pr | | | | | | |
| | ofile | | | | | | |
| | exte | | | | | | |
| | nsion | | | | | | |
+-------+-------+-------+-----+-------+------+-------+-------+
| HV | High | 1:1 | Y | Y | Y | Y | OVS-k |
| | P | | | | | | ernel |
| | erfor | | | | | | |
| | mance | | | | | | |
| | Pr | | | | | | |
| | ofile | | | | | | |
+-------+-------+-------+-----+-------+------+-------+-------+
| HD | High | 1:1 | Y | Y | Y | Y | OVS |
| | P | | | | | | -DPDK |
| | erfor | | | | | | |
| | mance | | | | | | |
| | Pr | | | | | | |
| | ofile | | | | | | |
| | with | | | | | | |
| | DPDK | | | | | | |
| | pr | | | | | | |
| | ofile | | | | | | |
| | exte | | | | | | |
| | nsion | | | | | | |
+-------+-------+-------+-----+-------+------+-------+-------+
| HS | High | 1:1 | Y | Y | Y | Y | S |
| | P | | | | | | R-IOV |
| | erfor | | | | | | |
| | mance | | | | | | |
| | Pr | | | | | | |
| | ofile | | | | | | |
| | with | | | | | | |
| | S | | | | | | |
| | R-IOV | | | | | | |
| | pr | | | | | | |
| | ofile | | | | | | |
| | exte | | | | | | |
| | nsion | | | | | | |
+-------+-------+-------+-----+-------+------+-------+-------+
.. raw:: html
Table 4-2: Profile Extensions and Capabilities
**BIOS Settings**
A number of capabilities need to be enabled in the BIOS (such as NUMA
and SMT); the Reference Model section on "`Cloud Infrastructure Software
profile description <../../../ref_model/chapters/chapter05.md#5.1>`__"
specifies where each of the capabilities is required to be configured.
Please note that capabilities may need to be configured in multiple
systems. For OpenStack, we also need to set the following boot
parameters:
=================== ====== ================
BIOS/boot Parameter Basic High Performance
=================== ====== ================
Boot disks RAID 1 RAID 1
=================== ====== ================
- How many nodes to meet SLA
- minimum: two nodes per profile
- HW specifications
- Boot disks are dedicated with Flash technology disks
- In case of DPDK usage:
+----------------------+----------------------------------------------+
| Layer | Description |
+======================+==============================================+
| Cloud infrastructure | Important is placement of NICs to get |
| | NUMA-balanced system (balancing the I/O, |
| | memory, and storage across both sockets), |
| | and configuration of NIC features. Server |
| | BIOS and Host OS kernel command line |
| | settings are described in `DPDK release |
| | note |
| | s `__ |
| | and `DPDK performance |
| | repo |
| | rts `__. |
| | Disabling power settings (like Intel Turbo |
| | Boost Technology) brings stable performance |
| | results, although understanding if and when |
| | they benefit workloads and enabling them can |
| | achieve better performance results. |
+----------------------+----------------------------------------------+
| Workload | DPDK uses core affinity along with 1G or 2M |
| | Huge Pages, NUMA settings (to avoid crossing |
| | inteconnect between CPUs), and DPDK Poll |
| | Mode Drivers (PMD, on reserved cores) to get |
| | the best performance. DPDK versions xx.11 |
| | are Long-Term Support maintained stable |
| | release with back-ported bug fixes for a |
| | two-year period. |
+----------------------+----------------------------------------------+
- Sizing rules
========================= ========
Description Mnemonic
========================= ========
Number of CPU sockets s
Number of cores c
SMT t
RAM rt
Storage d
Overcommit o
Average vCPU per instance v
Average RAM per instance ri
========================= ========
+----------------+----------------+----------------+----------------+
| | | Basic | High |
| | | | Performance |
+================+================+================+================+
| # of VMs per | ( | 4 | (s\ *c*\ t)/v |
| node (vCPU) | s\ *c*\ t*o)/v | *(s\ *c*\ t)/v | |
+----------------+----------------+----------------+----------------+
| # of VMs per | rt/ri | rt/ri | rt/ri |
| node (RAM) | | | |
+----------------+----------------+----------------+----------------+
| | | | |
+----------------+----------------+----------------+----------------+
| Max # of VMs | | min(4* | min( |
| per node | | (s\ *c*\ t)/v, | (s\ *c*\ t)/v, |
| | | rt/ri) | rt/ri) |
+----------------+----------------+----------------+----------------+
Caveats:
- These are theoretical limits
- Affinity and anti-affinity rules, among other factors, affect the
sizing
.. _4226-compute-resource-pooling-considerations:
4.2.2.6. Compute Resource Pooling Considerations
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
- Multiple pools of hardware resources where each resource pool caters
for workloads of a specific profile (for example, High Performance)
leads to inefficient use of the hardware as the server resources are
specific to the profile. If not properly sized or when demand changes
can lead to oversupply/starvation scenarios; reconfiguration may not
be possible because of the underlying hardware or inability to vacate
servers for reconfiguration to support another profile type.
- Single pool of hardware resources including for controllers have the
same CPU type. This is operationally efficient as any server can be
utilized to support any profile or controller. The single pool is
valuable with unpredictable workloads or when the demand of certain
profiles is insufficient to justify individual hardware selection.
.. _4227-reservation-of-compute-node-cores:
4.2.2.7. Reservation of Compute Node Cores
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
The `RA-1 2.3.2 Infrastructure
Requirements <./chapter02.md#232-infrastructure-requirements>`__
req.inf.com.08 requires the allocation of "certain number of host
cores/threads to non-tenant workloads such as for OpenStack services." A
number ("n") of random cores can be reserved for host services
(including OpenStack services) by specifying the following in nova.conf:
reserved_host_cpus = n
where n is any positive integer.
If we wish to dedicate specific cores for host processing we need to
consider two different use cases:
::
1. Require dedicated cores for Guest resources
2. No dedicated cores are required for Guest resources
Scenario #1, results in compute nodes that host both pinned and unpinned
workloads. In the OpenStack Train release, scenario #1 is not supported;
it may also be something that operators may not allow. Scenario #2 is
supported through the specification of the cpu_shared_set configuration.
The cores and their sibling threads dedicated to the host services are
those that do not exist in the cpu_shared_set configuration.
Let us consider a compute host with 20 cores with SMT enabled (let us
disregard NUMA) and the following parameters specified. The physical
cores are numbered '0' to '19' while the sibling threads are numbered
'20' to '39' where the vCPUs numbered '0' and '20', '1' and '21', etc.
are siblings:
cpu_shared_set = 1-7,9-19,21-27,29-39 (can also be
specified as cpu_shared_set = 1-19,^8,21-39,^28)
This implies that the two physical cores '0' and '8' and their sibling
threads '20' and '28' are dedicated to the host services, and 19 cores
and their sibling threads are available for Guest instances (and can be
over allocated as per the specified cpu_allocation_ratio in nova.conf.
.. _4228-pinned-and-unpinned-cpus:
4.2.2.8. Pinned and Unpinned CPUs
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
When a VM instance is created the vCPUs are, by default, not assigned to
a particular host CPU. Certain workloads require real-time or near
real-time behavior viz., uninterrupted access to their cores. For such
workloads, CPU pinning allows us to bind an instance’s vCPUs to
particular host cores or SMT threads. To configure a flavor to use
pinned vCPUs, we use a dedicated CPU policy.
openstack flavor set .xlarge --property hw:cpu_policy=dedicated
While an instance with pinned CPUs cannot use CPUs of another pinned
instance, this does not apply to unpinned instances; an unpinned
instance can utilize the pinned CPUs of another instance. To prevent
unpinned instances from disrupting pinned instances, the hosts with CPU
pinning enabled are pooled in their own host aggregate and hosts with
CPU pinning disabled are pooled in another non-overlapping host
aggregate.
.. _4229-compute-node-configurations-for-profiles-and-openstack-flavors:
4.2.2.9 Compute node configurations for Profiles and OpenStack Flavors
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
This section specifies the compute node configurations to support
profiles and flavors.
**Cloud Infrastructure Hardware Profile**
The Cloud Infrastructure Hardware (or simply “host”) profile and
configuration parameters are utilised in the reference architecture to
define different hardware profiles; these are used to configure the BIOS
settings on a physical server and configure utility software (such as
Operating System and Hypervisor).
An OpenStack flavor defines the characteristics (“capabilities”) of
Virtual Machines (VMs or vServers) that will be deployed on hosts
assigned a host-profile. A many to many relationship exists between
flavors and host profiles. Multiple flavors can be defined with
overlapping capability specifications with only slight variations that
VMs of these flavor types can be hosted on similary configured (host
profile) compute hosts. Similarly, a VM can be specified with a flavor
that allows it to be hosted on, say, a host configured as per the Basic
profile or a host configured as per the High Performance profile. Please
note that workloads that specify a VM flavor so as to be hosted on a
host configured as per the High Performance profile, may not be able to
run (adequately with expected performance) on a host configured as per
the Basic profile.
A given host can only be assigned a single host profile; a host profile
can be assigned to multiple hosts. Host profiles are immutable and hence
when a configuration needs to be changed, a new host profile is created.
**CPU Allocation Ratio and CPU Pinning**
A given host (compute node) can only support a single CPU Allocation
Ratio. Thus, to support the B1 and B4 Basic profile extensions with CPU
Allocation Ratios of 1.0 and 4.0 we will need to create 2 different host
profiles and separate host aggregates for each of the host profiles. The
CPU Allocation Ratio is set in the hypervisor on the host.
When the CPU Allocation Ratio exceeds 1.0 then CPU Pinning also needs
to be disabled.
**Server Configurations**
The different networking choices – OVS-Kernel, OVS-DPDK, SR-IOV – result
in different NIC port, LAG (Link Aggregation Group), and other
configurations. Some of these are shown diagrammatically in the next
section.
**Leaf and Compute Ports for Server Flavors must align**
Compute hosts have varying numbers of Ports/Bonds/LAGs/Trunks/VLANs
connected with Leaf ports. Each Leaf port (in A/B pair) must be
configured to align with the interfaces required for the compute flavor.
Physical Connections/Cables are generally the same within a zone,
regardless of these specific L2/L3/SR-IOV configurations for the compute
**Compute Bond Port:** TOR port maps VLANs directly with IRBs on the TOR
pair for tunnel packets and Control Plane Control and Storage packets.
These packets are then routed on the underlay network GRT.
Server Flavors: B1, B4, HV, HD
**Compute SR-IOV Port:** TOR port maps VLANs with bridge domains that
extend to IRBs, using VXLAN VNI. The TOR port associates each packet’s
outer VLAN tag with a bridge domain to support VNF interface adjacencies
over the local EVPN/MAC bridge domain. This model also applies to direct
physical connections with transport elements.
Server Flavors: HS
**Notes on SR-IOV**
SR-IOV at the Compute Server routes Guest traffic directly with a
partitioned NIC card, bypassing the hypervisor and vSwitch software,
which provides higher bps/pps throughput for the Guest VM. OpenStack and
MANO manage SR-IOV configurations for Tenant VM interfaces.
- Server, Linux, and NIC card hardware standards include SR-IOV and VF
requirements
- High Performance profile for SR-IOV (hs series) with specific
NIC/Leaf port configurations
- OpenStack supports SR-IOV provisioning
- Implement Security Policy, Tap/Mirror, QoS, etc. functions in the
NIC, Leaf, and other places
Because SR-IOV involves Guest VLANs between the Compute Server and the
ToR/Leafs, Guest automation and VM placement necessarily involves the
Leaf switches (e.g., access VLAN outer tag mapping with VXLAN EVPN).
- Local VXLAN tunneling over IP-switched fabric implemented between
VTEPs on Leaf switches.
- Leaf configuration controlled by SDN-Fabric/Global Controller.
- Underlay uses VXLAN-enabled switches for EVPN support
SR-IOV-based networking for Tenant Use Cases is required where
vSwitch-based networking throughput is inadequate.
**Example Host Configurations**
*Host configurations for B1, B4 Profile Extensions*
.. raw:: html
Figure 4-1: Basic Profile Host Configuration (example and simplified).
Let us refer to the data traffic networking configuration of Figure 4-1
to be part of the hp-B1-a and hp-B4-a host profiles and this requires
the configurations as Table 4-3.
+----------------+---------------+----------------+----------------+
| | Configured in | Host profile: | Host profile: |
| | | hp-B1-a | hp-B4-a |
+================+===============+================+================+
| CPU Allocation | Hypervisor | 1:1 | 4:1 |
| Ratio | | | |
+----------------+---------------+----------------+----------------+
| CPU Pinning | BIOS | Disable | Disable |
+----------------+---------------+----------------+----------------+
| SMT | BIOS | Enable | Enable |
+----------------+---------------+----------------+----------------+
| NUMA | BIOS | Disable | Disable |
+----------------+---------------+----------------+----------------+
| Huge Pages | BIOS | No | No |
+----------------+---------------+----------------+----------------+
| Profile | | B1 | B4 |
| Extensions | | | |
+----------------+---------------+----------------+----------------+
.. raw:: html
Table 4-3: Configuration of Basic Flavor Capabilities
Figure 4-2 shows the networking configuration where the storage and OAM
share networking but are independent of the PXE network.
.. raw:: html
Figure 4-2: Basic Profile Host Configuration with shared Storage and OAM networking (example and simplified).
Let us refer to the above networking set up to be part of the hp-B1-b
and hp-B4-b host profiles but the basic configurations as specified in
Table 4-3.
In our example, the Profile Extensions B1 and B4, are each mapped to two
different host profiles hp-B1-a and hp-B1-b, and hp-B4-a and hp-B4-b
respectively. Different network configurations, reservation of CPU
cores, Lag values, etc. result in different host profiles.
To ensure Tenant CPU isolation from the host services (Operating System
(OS), hypervisor and OpenStack agents), the following needs to be
configured
+----------------------+----------------------+----------------------+
| GRUB bootloader | Description | Values |
| Parameter | | |
+======================+======================+======================+
| isolcpus (Applicable | A set of cores | isolcpus=1-19, |
| only on Compute | isolated from the | 21-39, 41-59, 61-79 |
| Servers) | host processes. | |
| | Contains vCPUs | |
| | reserved for Tenants | |
+----------------------+----------------------+----------------------+
*Host configuration for HV Profile Extensions*
The above examples of host networking configurations for the B1 and B4
Profile Extensions are also suitable for the HV Profile Extensions;
however, the hypervisor and BIOS settings will be different (see table
below) and hence there will be a need for different host profiles. Table
4-4 gives examples of three different host profiles; one each for HV, HD
and HS Profile Extensions.
+-------------+-------------+-------------+-------------+-------------+
| | Configured | Host | Host | Host |
| | in | profile: | profile: | profile: |
| | | hp-hv-a | hp-hd-a | hp-hs-a |
+=============+=============+=============+=============+=============+
| Profile | | HV | HD | HS |
| Extensions | | | | |
+-------------+-------------+-------------+-------------+-------------+
| CPU | Hypervisor | 1:1 | 1:1 | 1:1 |
| Allocation | | | | |
| Ratio | | | | |
+-------------+-------------+-------------+-------------+-------------+
| NUMA | BIOS, | Enable | Enable | Enable |
| | Operating | | | |
| | System, | | | |
| | Hypervisor | | | |
| | and | | | |
| | OpenStack | | | |
| | Nova | | | |
| | Scheduler | | | |
+-------------+-------------+-------------+-------------+-------------+
| CPU Pinning | OpenStack | Enable | Enable | Enable |
| (requires | Nova | | | |
| NUMA) | Scheduler | | | |
+-------------+-------------+-------------+-------------+-------------+
| SMT | BIOS | Enable | Enable | Enable |
+-------------+-------------+-------------+-------------+-------------+
| Huge Pages | BIOS | Yes | Yes | Yes |
+-------------+-------------+-------------+-------------+-------------+
.. raw:: html
Table 4-4: Configuration of High Performance Flavor Capabilities
*Host Networking configuration for HD Profile Extensions*
An example of the data traffic configuration for the HD (OVS-DPDK)
Profile Extensions is shown in Figure 4-3.
.. raw:: html
Figure 4-3: High Performance Profile Host Configuration with DPDK acceleration (example and simplified).
To ensure Tenant and DPDK CPU isolation from the host services
(Operating System (OS), hypervisor and OpenStack agents), the following
needs to be configured
+----------------------+----------------------+----------------------+
| GRUB bootloader | Description | Values |
| Parameter | | |
+======================+======================+======================+
| isolcpus (Applicable | A set of cores | isolcpus=3-19, |
| only on Compute | isolated from the | 23-39, 43-59, 63-79 |
| Servers) | host processes. | |
| | Contains vCPUs | |
| | reserved for Tenants | |
| | and DPDK | |
+----------------------+----------------------+----------------------+
*Host Networking configuration for HS Profile Extensions*
An example of the data traffic configuration for the HS (SR-IOV) Profile
Extensions is shown in Figure 4-4.
.. raw:: html
Figure 4-4: High Performance Profile Host Configuration with SR-IOV (example and simplified).
To ensure Tenant CPU isolation from the host services (Operating System
(OS), hypervisor and OpenStack agents), the following needs to be
configured
+----------------------+----------------------+----------------------+
| GRUB bootloader | Description | Values |
| Parameter | | |
+======================+======================+======================+
| isolcpus (Applicable | A set of cores | isolcpus=1-19, |
| only on Compute | isolated from the | 21-39, 41-59, 61-79 |
| Servers) | host processes. | |
| | Contains vCPUs | |
| | reserved for Tenants | |
+----------------------+----------------------+----------------------+
**Using Hosts of a Host Profile type**
As we have seen Profile Extensions are supported by configuring hosts in
accordance with the Profile Extensions specifications. For example, an
instance of flavor type B1 can be hosted on a compute node that is
configured as an hp-B1-a or hp-B1-b host profile. All compute nodes
configured with hp-B1-a or hp-B1-b host profile are made part of a host
aggregate, say, ha-B1 and thus during VM instantiation of B1 flavor
hosts from the ha-B1 host aggregate will be selected.
.. _423-network-fabric:
4.2.3. Network Fabric
~~~~~~~~~~~~~~~~~~~~~
Networking Fabric consists of:
- Physical switches, routers…
- Switch OS
- Minimum number of switches
- Dimensioning for East/West and North/South
- Spine / Leaf topology – east – west
- Global Network parameters
- OpenStack control plane VLAN / VXLAN layout
- Provider VLANs
.. _4231-physical-network-topology:
4.2.3.1 Physical Network Topology
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
.. _4232-high-level-logical-network-layout:
4.2.3.2 High Level Logical Network Layout
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
.. raw:: html
Figure 4-5: Indicative OpenStack Network Layout.
+----------------------+----------------------+----------------------+
| Network | Description | Characteristics |
+======================+======================+======================+
| Provisioning & | Initial OS | Security Domain: |
| Management | bootstrapping of the | ManagementExternally |
| | servers via PXE, | Routable: |
| | deployment of | NoConnected to: All |
| | software and | nodes |
| | thereafter for | |
| | access from within | |
| | the control plane. | |
+----------------------+----------------------+----------------------+
| Internal API | Intra-OpenStack | Security Domain: |
| | service API | ManagementExternally |
| | communications, | Routable: No |
| | messaging and | Connected to: All |
| | database replication | nodes except |
| | | foundation |
+----------------------+----------------------+----------------------+
| Storage Management | Backend connectivity | Security Domain: |
| | between storage | Storage Externally |
| | nodes for | Routable: No |
| | heartbeats, data | Connected to: All |
| | object replication | nodes except |
| | and synchronisation | foundation |
+----------------------+----------------------+----------------------+
| Storage Front-end | Block/Object storage | Security Domain: |
| | access via | StorageExternally |
| | cinder/swift | Routable: |
| | | NoConnected to: All |
| | | nodes except |
| | | foundation |
+----------------------+----------------------+----------------------+
| Tenant | VXLAN / Geneve | Security Domain: |
| | project overlay | UnderlayExternally |
| | networks (OVS kernel | Routable: No |
| | mode) – i.e. RFC1918 | Connected to: |
| | re-usable private | controllers and |
| | networks as | computes |
| | controlled by cloud | |
| | administrator | |
+----------------------+----------------------+----------------------+
| External API | Hosts the public | Security Domain: |
| | OpenStack API | PublicExternally |
| | endpoints including | routable: |
| | the dashboard | YesConnected to: |
| | (Horizon) | controllers |
+----------------------+----------------------+----------------------+
| External Provider | Network with a pool | Security Domain: |
| (FIP) | of externally | Data |
| | routable IP | CentreExternally |
| | addresses used by | routable: |
| | neutron routers to | YesConnected to: |
| | NAT to/from the | controllers, OVS |
| | tenant RFC1918 | computes |
| | private networks | |
+----------------------+----------------------+----------------------+
| External Provider | External Data Centre | Security Domain: |
| (VLAN) | L2 networks (VLANs) | Data |
| | that are directly | CentreExternally |
| | accessible to the | routable: |
| | project. Note: | YesConnected to: OVS |
| | External IP address | DPDK computes |
| | management is | |
| | required | |
+----------------------+----------------------+----------------------+
| IPMI / Out of Band | The remote | Security Domain: |
| | “lights-out” | ManagementExternally |
| | management port of | routable: |
| | the servers e.g. | NoConnected to: IPMI |
| | iLO, IDRAC / IPMI / | port on all servers |
| | Redfish | |
+----------------------+----------------------+----------------------+
A VNF application network topology is expressed in terms of VMs, vNIC
interfaces with vNet access networks, and WAN Networks while the VNF
Application VMs require multiple vNICs, VLANs, and host routes
configured within the VM’s Kernel.
.. _4233-octavia-v2-api-conformant-load-balancing:
4.2.3.3. Octavia v2 API conformant Load Balancing
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
Load balancing is needed for automatic scaling, managing availability
and changes.
`Octavia `__
is an open-source load balancer for OpenStack, based on HAProxy, and
replaces the deprecated (as of OpenStack Queens release) Neutron LBaaS.
The Octavia v2 API is a superset of the deprecated Neutron LBaaS v2 API
and has a similar CLI for seamless transition.
As a default Octavia utilizes Amphorae Load Balancer. Amphorae consists
of a fleet of VMs, containers or bare metal servers and delivers
horizontal scaling by managing and spinning these resources on demand.
The reference implementation of the Amphorae image is an Ubuntu virtual
machine running HAProxy.
Octavia depends upon a number of OpenStack services including Nova for
spinning up compute resources on demand and their life cycle management;
Neutron for connectivity between the compute resources, project
environment and external networks; Keystone for authentication; and
Glance for storing of the compute resource images.
Octavia supports provider drivers which allows third-party load
balancing drivers (such as F5, AVI, etc.) to be utilized instead of the
default Amphorae load balancer. When creating a third-party load
balancer, the **provider** attribute is used to specify the backend to
be used to create the load balancer. The **list providers** lists all
enabled provider drivers. Instead of using the provider parameter, an
alternate is to specify the flavor_id in the create call where
provider-specific Octavia flavors have been created.
.. _4234-neutron-extensions:
4.2.3.4. Neutron Extensions
^^^^^^^^^^^^^^^^^^^^^^^^^^^
OpenStack Neutron is an extensible framework that allows incorporation
through plugins and API Extensions. API Extensions provides a method for
introducing new functionality and vendor specific capabilities. Neutron
plugins support new or vendor-specific functionality. Extensions also
allow specifying new resources or extensions to existing resources and
the actions on these resources. Plugins implement these resources and
actions.
Anuket Reference Architecture support the ML2 plugin (see below) as well
as the service plugins including for `FWaaS (Firewall as a
Service) `__,
`LBaaS (Load Balancer as a
Service) `__,
and `VPNaaS (VPN as a
Service) `__. The
OpenStack wiki provides a list of `Neutron
plugins `__.
Every Neutron plugin needs to implement a minimum set of common `methods
(actions for Train
release) `__.
Resources can inherit Standard Attributes and thereby have the
extensions for these standard attributes automatically incorporated.
Additions to resources, such as additional attributes, must be
accompanied by an extension.
`Chapter 5 `__, Interfaces and APIs, of this Reference
Architecture provides a list of `Neutron
Extensions `__. The current available
extensions can be obtained using `List Extensions
API `__
and details about an extension using `Show extension details
API `__.
**Neutron ML2 integration** The OpenStack Modular Layer 2 (ML2) plugin
simplifies adding networking technologies by utilizing drivers that
implement these network types and methods for accessing them. Each
network type is managed by an ML2 type driver and the mechanism driver
exposes interfaces to support the actions that can be performed on the
network type resources. The `OpenStack ML2
documentation `__ lists
example mechanism drivers.
.. _4235-network-quality-of-service:
4.2.3.5. Network quality of service
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
With support of VNF workloads, the resources bottlenecks are not only
the CPU and the memory but also the I/O bandwidth and the forwarding
capacity of virtual and non-virtual switches and routers within the
infrastructure. Several techniques (all complementary) can be used to
improve QoS and try to avoid any issue due to a network bottleneck
(mentioned per order of importance):
- Nodes interfaces segmentation: Have separated NIC ports for Storage
and Tenant networks. Actually, the storage traffic is bursty, and
especially in case of service restoration after some failure or new
service implementation, upgrades, etc. Control and management
networks should rely on a separate interface from the interface used
to handle tenant networks.
- Capacity planning: FW, physical links, switches, routers, NIC
interfaces and DCGW dimensioning (+ load monitoring: each link within
a LAG or a bond shouldn’t be loaded over 50% of its maximum capacity
to guaranty service continuity in case of individual failure).
- Hardware choice: e.g. ToR/fabric switches, DCGW and NIC cards should
have appropriate buffering and queuing capacity.
- High Performance compute node tuning (including OVS-DPDK).
.. _4236-integration-interfaces:
4.2.3.6. Integration Interfaces
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
- DHCP When the Neutron-DHCP agent is hosted in controller nodes, then
for VMs, on a Tenant network, that need to acquire an IPv4 and/or
IPv6 address, the VLAN for the Tenant must be extended to the control
plane servers so that the Neutron agent can receive the DHCP requests
from the VM and send the response to the VM with the IPv4 and/or IPv6
addresses and the lease time. Please see OpenStack provider Network.
- DNS
- LDAP
- IPAM
.. _424-storage-backend:
4.2.4. Storage Backend
~~~~~~~~~~~~~~~~~~~~~~
Storage systems are available from multiple vendors and can also utilize
commodity hardware from any number of Open Source based storage packages
(such as LVM, Ceph, NFS, etc.). The proprietary and open-source storage
systems are supported in Cinder through specific plugin drivers. The
OpenStack `Cinder
documentation `__
specifies the minimum functionality that all storage drivers must
support. The functions include:
- Volume: create, delete, attach, detach, extend, clone (volume from
volume), migrate
- Snapshot: create, delete and create volume from snapshot
- Image: create from volume
The document also includes a matrix for a number of proprietary drivers
and some of the optional functions that these drivers support. This
matrix is a handy tool to select storage backends that have the optional
storage functions needed by the cloud operator. The cloud workload
storage requirements helps determine the backends that should be
deployed by the cloud operator. The common storage backend attachment
methods include iSCSI, NFS, local disk, etc. and the matrix list the
supported methods for each of the vendor drivers. The OpenStack Cinder
`Available
Drivers `__
documentation provides a list of all OpenStack compatible drivers and
their configuration options.
The `Cinder
Configuration `__
document provides information on how to configure cinder including
Anuket required capabilities for volume encryption, Policy
configuration, quotas, etc. The `Cinder
Administration `__
document provides information on the capabilities required by Anuket
including managing volumes, snapshots, multi-storage backends, migrate
volumes, etc.
`Ceph `__ is the default Anuket Reference Architecture
storage backend and is discussed below.
.. _4241-ceph-storage-cluster:
4.2.4.1. Ceph Storage Cluster
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
The Ceph storage cluster is deployed on bare metal hardware. The minimal
configuration is a cluster of three bare metal servers to ensure High
availability. The Ceph Storage cluster consists of the following
components:
- CEPH-MON (Ceph Monitor)
- OSD (object storage daemon)
- RadosGW (Rados Gateway)
- Journal
- Manager
Ceph monitors maintain a master copy of the maps of the cluster state
required by Ceph daemons to coordinate with each other. Ceph OSD handle
the data storage (read/write data on the physical disks), data
replication, recovery, rebalancing, and provides some monitoring
information to Ceph Monitors. The RadosGW provides Object Storage
RESTful gateway with a Swift-compatible API for Object Storage.
.. raw:: html
![Ceph Storage System](../figures/RA1-Ch04-Ceph.png)
Figure 4-6: Ceph Storage System.
**BIOS Requirement for Ceph servers**
=================== ======
BIOS/boot Parameter Value
=================== ======
Boot disks RAID 1
=================== ======
How many nodes to meet SLA :
- minimum: three bare metal servers where Monitors are collocated with
OSD. Note: at least 3 Monitors and 3 OSDs are required for High
AVailability.
HW specifications :
- Boot disks are dedicated with Flash technology disks
- For an IOPS oriented cluster (Flash technology ), the journal can be
hosted on OSD disks
- For a capacity oriented cluster (HDD), the journal must be hosted on
dedicated Flash technology disks
Sizing rules :
- Minimum of 6 disks per server
- Replication factor : 3
- 1 Core-GHz per OSD
- 16GB RAM baseline + 2-3 GB per OSD
.. _43-virtualised-infrastructure-manager-vim:
4.3 Virtualised Infrastructure Manager (VIM)
--------------------------------------------
This section covers:
- Detailed breakdown of OpenStack core services
- Specific build-time parameters
.. _431-vim-services:
4.3.1 VIM Services
~~~~~~~~~~~~~~~~~~
A high level overview of the core OpenStack Services was provided in
`Chapter 3 <./chapter03.md>`__. In this section we describe the core and
other needed services in more detail.
.. _4311-keystone:
4.3.1.1 Keystone
^^^^^^^^^^^^^^^^
Keystone is the authentication service, the foundation of identity
management in OpenStack. Keystone needs to be the first deployed
service. Keystone has services running on the control nodes and no
services running on the compute nodes:
- Keystone admin API
- Keystone public API – in Keystone V3 this is the same as the admin
API,
.. _4312-glance:
4.3.1.2 Glance
^^^^^^^^^^^^^^
Glance is the image management service. Glance has only a dependency on
the Keystone service therefore it is the second one deployed. Glance has
services running on the control nodes and no services running on the
compute nodes:
- Glance API
- Glance Registry
*The Glance backends include Swift, Ceph RBD and NFS*
.. _4313-cinder:
4.3.1.3 Cinder
^^^^^^^^^^^^^^
Cinder is the block device management service, Cinder depends on
Keystone and possibly Glance to be able to create volumes from images.
Cinder has services running on the control nodes and no services running
on the compute nodes:
- Cinder API
- Cinder Scheduler
- Cinder Volume – the Cinder volume process needs to talk to its
backends
*The Cinder backends include SAN/NAS storage, iSCSI drives, Ceph RBD and
NFS.*
.. _4314-swift:
4.3.1.4 Swift
^^^^^^^^^^^^^
Swift is the object storage management service, Swift depends on
Keystone and possibly Glance to be able to create volumes from images.
Swift has services running on the control nodes and the compute nodes:
- Proxy Services
- Object Services
- Container Services
- Account Services
*The Swift backends include iSCSI drives, Ceph RBD and NFS.*
.. _4315-neutron:
4.3.1.5 Neutron
^^^^^^^^^^^^^^^
Neutron is the networking service, Neutron depends on Keystone and has
services running on the control nodes and the compute nodes. Depending
upon the workloads to be hosted by the Infrastructure and the expected
load on the controller node, some of the Neutron services can run on
separate network node(s). Factors affecting controller node load include
number of compute nodes and the number of API calls being served for the
various OpenStack services (nova, neutron, cinder, glance etc.). To
reduce controller node load, network nodes are widely added to manage L3
traffic for overlay tenant networks and interconnection with external
networks. Table 4-2 below lists the networking service components and
their placement. Please note that while network nodes are listed in the
table below, network nodes only deal with tenant networks and not
provider networks. Also, network nodes are not required when SDN is
utilized for networking.
+----------------+----------------+----------------+----------------+
| Networking | Description | Required or | Placement |
| Service | | Optional | |
| component | | Service | |
+================+================+================+================+
| neutron server | Manages user | Required | Controller |
| ( | requests and | | node |
| neutron-server | exposes the | | |
| and | Neutron APIs | | |
| neu | | | |
| tron-*-plugin) | | | |
+----------------+----------------+----------------+----------------+
| DHCP agent | Provides DHCP | Optional | Network node |
| (neutr | services to | depending upon | (Controller |
| on-dhcp-agent) | tenant | plug-in | node if no |
| | networks and | | network node |
| | is responsible | | present) |
| | for | | |
| | maintaining | | |
| | DHCP | | |
| | configuration. | | |
| | For High | | |
| | availability, | | |
| | multiple DHCP | | |
| | agents can be | | |
| | assigned. | | |
+----------------+----------------+----------------+----------------+
| L3 agent | Provides | Optional | Network node |
| (neu | L3/NAT | depending upon | (Controller |
| tron-l3-agent) | forwarding for | plug-in | node if no |
| | external | | network node |
| | network access | | present) NB in |
| | of VMs on | | DVR based |
| | tenant | | OpenStack |
| | networks and | | Networking, |
| | supports | | also in all |
| | services such | | Compute nodes. |
| | as | | |
| | Firewal | | |
| | l-as-a-service | | |
| | (FWaaS) and | | |
| | Load | | |
| | Balance | | |
| | r-as-a-service | | |
| | (LBaaS) | | |
+----------------+----------------+----------------+----------------+
| neutron | The metadata | Optional | Network node |
| metadata agent | service | | (Controller |
| (neutron-m | provides a way | | node if no |
| etadata-agent) | for instances | | network node |
| | to retrieve | | present) |
| | ins | | |
| | tance-specific | | |
| | data. The | | |
| | networking | | |
| | service, | | |
| | neutron, is | | |
| | responsible | | |
| | for | | |
| | intercepting | | |
| | these requests | | |
| | and adding | | |
| | HTTP headers | | |
| | which uniquely | | |
| | identify the | | |
| | source of the | | |
| | request before | | |
| | forwarding it | | |
| | to the | | |
| | metadata API | | |
| | server. These | | |
| | functions are | | |
| | performed by | | |
| | the neutron | | |
| | metadata | | |
| | agent. | | |
+----------------+----------------+----------------+----------------+
| neutron plugin | Runs on each | Required | Every Compute |
| agent | compute node | | Node |
| (ne | to control and | | |
| utron-*-agent) | manage the | | |
| | local virtual | | |
| | network driver | | |
| | (such as the | | |
| | Open vSwitch | | |
| | or Linux | | |
| | Bridge) | | |
| | configuration | | |
| | and local | | |
| | networking | | |
| | configuration | | |
| | for VMs hosted | | |
| | on that node. | | |
+----------------+----------------+----------------+----------------+
.. raw:: html
Table 4-2: Neutron Services Placement
**Issues with the standard networking (centralized routing) approach**
The network node performs both routing and NAT functions and represents
both a scaling bottleneck and a single point of failure.
Two VMs on different compute nodes and using different project networks
(a.k.a. tenant networks) where the both of the project networks are
connected by a project router. For communication between the two VMs
(instances with a fixed or floating IP address), the network node routes
East-West network traffic among project networks using the same project
router. Even though the instances are connected by a router, all routed
traffic must flow through the network node, and this becomes a
bottleneck for the whole network.
While the separation of the routing function from the controller node to
the network node provides a degree of scaling it is not a truly scalable
solution. We can either add additional cores/compute-power or network
node to the network node cluster, but, eventually, it runs out of
processing power especially with high throughput requirement. Therefore,
for scaled deployments, there are multiple options including use of
Dynamic Virtual Routing (DVR) and Software Defined Networking (SDN).
**Distributed Virtual Routing (DVR)**
With DVR, each compute node also hosts the L3-agent (providing the
distributed router capability) and this then allows direct instance to
instance (East-West) communications.
The OpenStack “\ `High Availability Using Distributed Virtual Routing
(DVR) `__\ ”
provides an in depth view into how DVR works and the traffic flow
between the various nodes and interfaces for three different use cases.
Please note that DVR was introduced in the OpenStack Juno release and,
thus, its detailed analysis in the Liberty release documentation is not
out of character for OpenStack documentation.
DVR addresses both scalability and high availability for some L3
functions but is not fully fault tolerant. For example, North/South SNAT
traffic is vulnerable to single node (network node) failures. `DVR with
VRRP `__
addresses this vulnerability.
**Software Defined Networking (SDN)**
For the most reliable solution that addresses all the above issues and
Telco workload requirements requires SDN to offload Neutron calls.
SDN provides a truly scalable and preferred solution to suport dynamic,
very large-scale, high-density, telco cloud environments. OpenStack
Neutron, with its plugin architecture, provides the ability to integrate
SDN controllers ( `3.2.5. Virtual Networking – 3rd party SDN
solution <./chapter03.md#325-virtual-networking--3rd-party-sdn-solution>`__).
With SDN incorporated in OpenStack, changes to the network is triggered
by workloads (and users), translated into Neutron APIs and then handled
through neutron plugins by the corresponding SDN agents.
.. _4316-nova:
4.3.1.6 Nova
^^^^^^^^^^^^
Nova is the compute management service, Nova depends on all above
components and is deployed after. Nova has services running on the
control nodes and the compute nodes:
- nova-metadata-api
- nova-compute api
- nova-consoleauth
- nova-scheduler
- nova-conductor
- nova-novncproxy
- nova-compute-agent which runs on Compute node
Please note that the Placement-API must have been installed and
configured prior to nova compute starts.
.. _4317-ironic:
4.3.1.7 Ironic
^^^^^^^^^^^^^^
Ironic is the bare metal provisioning service. Ironic depends on all
above components and is deployed after. Ironic has services running on
the control nodes and the compute nodes:
- Ironic API
- ironic-conductor which executes operation on bare metal nodes
Note: This is an optional service. As Ironic is currently not invoked
directly (only invoked through other services such as Nova) hence its
APIs will not be specified.
.. _4318-heat:
4.3.1.8 Heat
^^^^^^^^^^^^
Heat is the orchestration service using template to provision cloud
resources, Heat integrates with all OpenStack services. Heat has
services running on the control nodes and no services running on the
compute nodes:
- heat-api
- heat-cfn-api
- heat-engine
.. _4319-horizon:
4.3.1.9 Horizon
^^^^^^^^^^^^^^^
Horizon is the Web User Interface to all OpenStack services. Horizon has
services running on the control nodes and no services running on the
compute nodes.
.. _43110-placement:
4.3.1.10 Placement
^^^^^^^^^^^^^^^^^^
The OpenStack `Placement
service `__
enables tracking (or accounting) and scheduling of resources. It
provides a RESTful API and a data model for the managing of resource
provider inventories and usage for different classes of resources. In
addition to standard resource classes, such as vCPU, MEMORY_MB and
DISK_GB, the Placement service supports custom resource classes
(prefixed with “CUSTOM_”) provided by some external resource pools such
as a shared storage pool provided by, say, Ceph. The placement service
is primarily utilized by nova-compute and nova-scheduler. Other
OpenStack services such as Neutron or Cyborg can also utilize placement
and do so by creating `Provider
Trees `__.
The following data objects are utilized in the `placement
service `__:
Resource Providers provide consumable inventory of one or more classes
of resources (CPU, memory or disk). A resource provider can be a compute
host, for example.
Resource Classes specifies the type of resources (vCPU, MEMORY_MB and
DISK_GB or CUSTOM_*)
Inventory: Each resource provider maintains the total and reserved
quantity of one or more classes of resources. For example, RP_1 has
available inventory of 16 vCPU, 16384 MEMORY_MB and 1024 DISK_GB.
Traits are qualitative characteristics of the resources from a resource
provider. For example, the trait for RPA_1 “is_SSD” to indicate that the
DISK_GB provided by RP_1 are solid state drives.
Allocations represent resources that have been assigned/used by some
consumer of that resource.
Allocation candidates is the collection of resource providers that can
satisfy an allocation request.
The Placement API is stateless and, thus, resiliency, availability and
scaling, it is possible to deploy as many servers as needed. On start,
the nova-compute service will attempt to make a connection to the
Placement API and keep attempting to connect to the Placement API,
logging and warning periodically until successful. Thus, the Placement
API must be installed and enabled prior to Nova compute.
Placement has services running on the control node:
- nova-placement-api
.. _43111-barbican:
4.3.1.11 Barbican
^^^^^^^^^^^^^^^^^
`Barbican `__ is the
OpenStack Key Manager service. It is an optional service hosted on
controller nodes. It provides secure storage, provisioning and
management of secrets as passwords, encryption keys and X.509
Certificates. Barbican API is used to centrally manage secrets used by
OpenStack services, e.g. symmetric encryption keys used for Block
storage encryption or Object Storage encryption or asymmetric keys and
certificates used for Glance image signing and verification.
Barbican usage provides a means to fulfill security requirements such as
sec.sys.012 “The Platform **must** protect all secrets by using strong
encryption techniques and storing the protected secrets externally from
the component” and sec.ci.001 “The Platform **must** support
Confidentiality and Integrity of data at rest and in transit.”.
.. raw:: html
.. _432-containerised-openstack-services:
4.3.2. Containerised OpenStack Services
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Containers are lightweight compared to Virtual Machines and leads to
efficient resource utilization. Kubernetes auto manages scaling,
recovery from failures, etc. Thus, it is recommended that the OpenStack
services be containerized for resiliency and resource efficiency.
In Chapter 3, `Figure
3.2 <../figures/RA1-Ch03-OpenStack-Services-Topology.png>`__ shows a
high level Virtualised OpenStack services topology. The containerized
OpenStack services topology version is shown in Figure 4-7.
.. raw:: html
![Containerised OpenStack Services Topology](../figures/RA1-Ch04-Containerised-OpenStack-Services-Stack.png)
Figure 4-7: Containerised OpenStack Services Topology.
.. _44-consumable-infrastructure-resources-and-services:
4.4 Consumable Infrastructure Resources and Services
----------------------------------------------------
.. _441-support-for-cloud-infrastructure-profiles-and-flavors:
4.4.1. Support for Cloud Infrastructure Profiles and flavors
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Reference Model Chapter 4 and 5 provide information about the Cloud
Infrastructure Profiles and their size information. OpenStack flavors
with their set of properties describe the VM capabilities and size
required to determine the compute host which will run this VM. The set
of properties must match compute profiles available in the
infrastructure. To implement these profiles and sizes, it is required to
set up the flavors as specified in the tables below.
+----------------+----------------+----------------+----------------+
| Flavor | ReferenceRM | Basic | High |
| Capabilities | Chapter 4 and | | Performance |
| | 5 | | |
+================+================+================+================+
| CPU allocation | inf | In flavor | In flavor |
| ratio (custom | ra.com.cfg.001 | create or | create or |
| extra_specs) | | flavor set | flavor set |
| | | --property | --property |
| | | cpu_alloca | cpu_alloca |
| | | tion_ratio=4.0 | tion_ratio=1.0 |
+----------------+----------------+----------------+----------------+
| NUMA Awareness | inf | | In flavor |
| | ra.com.cfg.002 | | create or |
| | | | flavor set |
| | | | spe |
| | | | cify--property |
| | | | hw:numa_ |
| | | | nodes=To restrict |
| | | | an instance's |
| | | | vCPUs to a |
| | | | single host |
| | | | NUMA node, |
| | | | specify: |
| | | | --property |
| | | | hw:nu |
| | | | ma_nodes=1Some |
| | | | compute |
| | | | intensive\* |
| | | | workloads with |
| | | | highly |
| | | | sensitive |
| | | | memory latency |
| | | | or bandwidth |
| | | | requirements, |
| | | | the instance |
| | | | may benefit |
| | | | from spreading |
| | | | across |
| | | | multiple NUMA |
| | | | nodes: |
| | | | --property |
| | | | h |
| | | | w:numa_nodes=2 |
+----------------+----------------+----------------+----------------+
| CPU Pinning | inf | In flavor | In flavor |
| | ra.com.cfg.003 | create or | create or |
| | | flavor set | flavor set |
| | | specify | specify |
| | | --property | --property |
| | | hw:cpu | hw:cpu_po |
| | | _policy=shared | licy=dedicated |
| | | (default) | and--property |
| | | | hw:cpu__ |
| | | | thread_policy= |
| | | | Use |
| | | | "isolate" |
| | | | thread policy |
| | | | for very high |
| | | | compute |
| | | | intensive |
| | | | workloads that |
| | | | require that |
| | | | each vCPU be |
| | | | placed on a |
| | | | different |
| | | | physical core |
+----------------+----------------+----------------+----------------+
| Huge Pages | inf | | --property |
| | ra.com.cfg.004 | | hw:mem_pa |
| | | | ge_size= |
+----------------+----------------+----------------+----------------+
| SMT | inf | | In flavor |
| | ra.com.cfg.005 | | create or |
| | | | flavor set |
| | | | specify |
| | | | --property |
| | | | hw:cpu_th |
| | | | reads= |
+----------------+----------------+----------------+----------------+
| OVS-DPDK | infra.n | | ml2.conf.ini |
| | et.acc.cfg.001 | | configured to |
| | | | support [OVS] |
| | | | datapa |
| | | | th_type=netdev |
| | | | Note: huge |
| | | | pages should |
| | | | be configured |
| | | | to large |
+----------------+----------------+----------------+----------------+
| Local Storage | infra.hw.s | tra | tra |
| SSD | tg.ssd.cfg.002 | it:STORAGE_DIS | it:STORAGE_DIS |
| | | K_SSD=required | K_SSD=required |
+----------------+----------------+----------------+----------------+
| Port speed | infra. | --property | --property |
| | hw.nic.cfg.002 | quota | quota |
| | | vif_inbound_a | vif_inbound_a |
| | | verage=1310720 | verage=3125000 |
| | | andvif_o | and |
| | | utbound_averag | vif_o |
| | | e=1310720Note: | utbound_averag |
| | | 10 Gbps = | e=3125000Note: |
| | | 1250000 | 25 Gbps = |
| | | kilobytes per | 3125000 |
| | | second | kilobytes per |
| | | | second |
+----------------+----------------+----------------+----------------+
..
- For example as defined in `Reference Model Profile
Extensions <../../../ref_model/chapters/chapter02.md#242-profile-extensions-specialisations>`__.
In addition, to configure the storage IOPS the following two parameters
need to be specified in the flavor create: --property
quota:disk_write_iops_sec= and --property
quota:disk_read_iops_sec=.
The flavor create command and the mandatory and optional configuration
parameters is documented in
`https://docs.openstack.org/nova/latest/user/flavors.html `__.
.. _442-logical-segregation-and-high-availability:
4.4.2. Logical segregation and high availability
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
To Ensure Logical segregation and high availability, the architecture
will rely on the following principles:
- Availability zone: provide resiliency and fault tolerance for VNF
deployments, by means of physical hosting distribution of Compute
Nodes in separate racks with separate power supply, in the same or
different DC room
- Affinity-groups: allow tenants to make sure that VNFC instances are
on the same compute node or are on different compute nodes.
Note: The Cloud Infrastructure doesn’t provide any resiliency mechanisms
at the service level. Any VM restart shall be triggered by the VNF
Manager instead of OpenStack:
- It doesn’t implement Instance High Availability which could allow
OpenStack Platform to automatically re-spawn instances on a different
Compute node when their host Compute node breaks.
- Physical host reboot does not trigger automatic VM recovery.
- Physical host reboot does not trigger the automatic start of VM
**Limitations and constraints**
- NUMA Overhead: isolated core will be used for overhead tasks from the
hypervisor
.. _443-transaction-volume-considerations:
4.4.3. Transaction Volume Considerations
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Storage transaction volumes impose a requirement on North-South network
traffic in and out of the storage backend. Data availability requires
that the data be replicated on multiple storage nodes and each new write
imposes East-West network traffic requirements.
.. _45-cloud-topology-and-control-plane-scenarios:
4.5 Cloud Topology and Control Plane Scenarios
----------------------------------------------
Typically, Clouds have been implemented in large (central) data centers
with 100' to tens of thousands of servers. Telco Operators have also
been creating intermediate data centers in central office locations,
colocation centers, and now edge centers at the physical edge of their
networks because of the demand for low latency and high throughput for
5G, IoT and connected devices (including autonomous driverless vehicles
and connected vehicles). Chapter 3 of this document, discusses `Cloud
Topology <./chapter03.md#3.5>`__ and lists 3 types of data centers:
Large, Intermediate and Edge.
For ease of convenience, unless specifically required, in this section
we will use Central Cloud Center, Edge Cloud Center and Intermediate
Cloud Center as representative terms for cloud services hosted at
centralised large data centers, Telco edge locations and for locations
with capacity somewhere in between the large data centers and edge
locations, respectively. The mapping of various terms, including the
Reference Model terminology specified in Table
`8-5 <../../..//ref_model/chapters/chapter08.md#8.3.5>`__ and `Open
Glossary of Edge
Computing `__
is as follows:
- Central Cloud Center: Large Centralised Data Center, Regional Data
Center
- Intermediate Cloud Center: Metro Data Center, Regional Edge,
Aggregation Edge
- Edge Cloud Center: Edge, Mini-/Micro-Edge, Micro Modular Data Center,
Service Provider Edge, Access Edge, Aggregation Edge
In the Intermediate and Edge cloud centers, there may be limitations on
the resource capacity, as in the number of servers, and the capacity of
these servers in terms of # of cores, RAM, etc. restricting the set of
services that can be deployed and, thus, creating a dependency between
other data centers. In `Reference Model Chapter
8.3 <../../../ref_model/chapters/chapter08.md#8.3>`__, Table 8-5
specifies the physical and environmental characteristics, infrastructure
capabilities and deployment scenarios of different locations.
Chapter `3.3.1.1. OpenStack Services
Topology <./chapter03.md#3311-openstack-services-topology>`__ of this
document, specifies the differences between the Control Plane and Data
Plane, and specifies which of the control nodes, compute nodes, storage
nodes (optional) and network nodes (optional) are components of these
planes. The previous sections of Chapter 4 include a description of the
OpenStack services and their deployment in control nodes, compute nodes,
and optionally storage nodes and network nodes (rarely). The Control
Plane deployment scenarios determine the distribution of OpenStack and
other needed services among the different node types. This section
considers the Centralised Control Plane (CCP) and Distributed Control
Plane (DCP) scenarios. The choice of control plane and the cloud center
resource capacity and capabilities determine the deployment of OpenStack
services in the different node types.
The Central Cloud Centers are organized around a Centralised Control
Plane. With the introduction of Intermediate and Edge Cloud Centers, the
Distributed Control Plane deployment becomes a possibility. A number of
independent control planes (sometimes referred to as Local Control
Planes (LCP)) exist in the Distributed Control Plane scenario, compared
with a single control plane in the Centralised Control Plane scenario.
Thus, in addition to the control plane and controller services deployed
at the Central Cloud Center, Local Control Planes hosting a full-set or
subset of the controller services are also deployed on the Intermediate
and Edge Cloud Centers. Table 4-5 presents examples of such deployment
choices.
+-------+-------+-------+-------+-------+-------+-------+-------+
| | | Orc | Ide | Image | Co | Ne | St |
| | | hestr | ntity | Manag | mpute | twork | orage |
| | | ation | Manag | ement | | Manag | Manag |
| | | | ement | | | ement | ement |
+=======+=======+=======+=======+=======+=======+=======+=======+
| CCP | C | heat | Ide | G | no | ne | C |
| | entra | -api, | ntity | lance | va-co | utron | inder |
| | lised | heat- | Pro | API, | mpute | -serv | API,C |
| | DC – | engin | vider | G | api | er,ne | inder |
| | co | e,nov | (IdP | lance | ,nova | utron | S |
| | ntrol | a-pla | ),Key | Reg | -sche | -dhcp | chedu |
| | nodes | cemen | stone | istry | duler | -agen | ler,C |
| | | t-api | API | | ,nova | t,neu | inder |
| | | | | | -cond | tron- | V |
| | | | | | uctor | L2-ag | olume |
| | | | | | | ent,n | |
| | | | | | | eutro | |
| | | | | | | n-L3- | |
| | | | | | | agent | |
| | | | | | | (op | |
| | | | | | | tiona | |
| | | | | | | l),ne | |
| | | | | | | utron | |
| | | | | | | -meta | |
| | | | | | | data- | |
| | | | | | | agent | |
+-------+-------+-------+-------+-------+-------+-------+-------+
| DCP: | Any | heat | Ide | G | no | ne | C |
| c | DC - | -api, | ntity | lance | va-co | utron | inder |
| ombin | Co | heat- | Pro | API, | mpute | -serv | API,C |
| ation | ntrol | engin | vider | G | api | er,ne | inder |
| of | nodes | e,nov | (IdP | lance | ,nova | utron | S |
| ser | O | a-pla | ),Key | Reg | -sche | -dhcp | chedu |
| vices | ption | cemen | stone | istry | duler | -agen | ler,C |
| depe | 1 | t-api | API | | ,nova | t,neu | inder |
| nding | | | | | -cond | tron- | V |
| upon | | | | | uctor | L2-ag | olume |
| C | | | | | | ent,n | |
| enter | | | | | | eutro | |
| size | | | | | | n-L3- | |
| | | | | | | agent | |
| | | | | | | (op | |
| | | | | | | tiona | |
| | | | | | | l),ne | |
| | | | | | | utron | |
| | | | | | | -meta | |
| | | | | | | data- | |
| | | | | | | agent | |
+-------+-------+-------+-------+-------+-------+-------+-------+
| | Any | \*\* | \* in | \* in | \*\* | \*\* | \*\* |
| | DC - | in | Large | Large | in | in | in |
| | Co | other | DC | DC | an | an | an |
| | ntrol | DC | | | other | other | other |
| | nodes | | | | DC | DC | DC |
| | O | | | | | | |
| | ption | | | | | | |
| | 2: | | | | | | |
| | split | | | | | | |
| | ser | | | | | | |
| | vices | | | | | | |
| | be | | | | | | |
| | tween | | | | | | |
| | DCs | | | | | | |
+-------+-------+-------+-------+-------+-------+-------+-------+
| CCP | Co | | | | nov | ne | |
| or | mpute | | | | a-com | utron | |
| DCP | nodes | | | | pute- | -L2-a | |
| | | | | | agent | gent, | |
| | | | | | | n | |
| | | | | | | eutro | |
| | | | | | | n-L3- | |
| | | | | | | agent | |
| | | | | | | (opti | |
| | | | | | | onal) | |
+-------+-------+-------+-------+-------+-------+-------+-------+
| CCP | Co | nov | | | nov | ne | |
| | mpute | a-pla | | | a-com | utron | |
| | nodes | cemen | | | pute- | -serv | |
| | | t-api | | | agent | er,ne | |
| | | | | | ,nova | utron | |
| | | | | | -cond | -dhcp | |
| | | | | | uctor | -agen | |
| | | | | | | t,neu | |
| | | | | | | tron- | |
| | | | | | | L2-ag | |
| | | | | | | ent,n | |
| | | | | | | eutro | |
| | | | | | | n-L3- | |
| | | | | | | agent | |
| | | | | | | (opti | |
| | | | | | | onal) | |
+-------+-------+-------+-------+-------+-------+-------+-------+
.. raw:: html
Table 4-5: Distribution of OpenStack services on different nodes depending upon Control Plane Scenario
.. _451-edge-cloud-topology:
4.5.1 Edge Cloud Topology
~~~~~~~~~~~~~~~~~~~~~~~~~
The Reference Model Chapter 8.3 "`Telco Edge
Cloud <../../../ref_model/chapters/chapter08.md#8.3>`__", presents the
deployment environment characteristics, infrastructure characteristics
and new values for the Infrastructure Profiles at the Edge.
The `Edge computing
whitepaper `__
includes information such as the services that run on various nodes. The
information from the whitepaper coupled with that from the `OpenStack
Reference
Architecture `__
for 100, 300 and 500 nodes will help in deciding which OpenStack and
other services (such as database, messaging) run on which nodes in what
Cloud Center and the number of copies that should be deployed. These
references also present the pros and cons of DCP and CCP and designs to
address some of the challenges of each of the models.
Table 8-4 in the Reference Model Chapter 8.3.4 "`Telco Edge Cloud:
Platform Services
Deployment <../../../ref_model/chapters/chapter08.md#8.3.4>`__" lists
the Platform Services that may be placed in the different node types
(control, compute and storage). Depending upon the capacity and
resources available only the compute nodes may exist at the Edge thereby
impacting operations.
Table 8-3 in the Reference Model Chapter 8.3.3 "`Telco Edge Cloud
Infrastructure
Profiles <../../../ref_model/chapters/chapter08.md#8.3.3>`__", lists a
number of Infrastructure Profile characteristics and the changes that
may need to be made for certain Edge clouds depending upon their
resource capabilities. It should be noted that none of these changes
affect the definition of OpenStack flavours.
.. _4511-edge-cloud-deployment:
4.5.1.1 Edge Cloud Deployment
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
Deployment at the Edge requires support for large scale deployment. A
number of open-source tools are available for the purpose including:
- `Airship `__: declaratively configure,
deploy and maintain an integrated virtualization and containerization
platform
- `Starling-X `__: cloud infrastructure
software stack for the edge
- `Triple-O `__: for
installing, upgrading and operating OpenStack clouds
The Reference Implementation (RI1) is responsible to choose the tools
for the implementation and shall specify implementation and usage